logo

East West Infiniti Pvt Ltd.

...where electronic technology speaks

EX80 Insertion MAGMeters

Fixed depth electromagnetic insertion flow meters

Features

  • Low-flow performance and accuracy superior to any mechanical flow sensor
  • No moving parts to wear out
  • Dedicated fittings for simplicity
  • Retainer clip automatically sets correct depth
  • Meter extends only about 1/8 of pipe diameter, minimizing potential for clogging with debris
  • Simple pulse train output can be used with most signal processing modules, or sent directly to a PLC
  • Available for pipe sizes 1 to 12 inch, in 316 stainless and PVC

Specifications

Accuracy: 1% of full scale

Output: Square wave pulse, opto isolated, 500 Hz @ 20 ft/sec

Bi-Directional: Direction output, opto isolated

Empty Pipe Detection: Flow defaults to zero

Flow Range: 0.2 - 20 ft/sec (.06 - 6.09 m/sec)

Maximum Pipe Pressure: 200 PSI (13.8 bar)

Maximum Temperature:

PVC 130° F (55° C)

Stainless Steel 200° F (93° C)

Minimum Conductivity: 20 microsiemens/cm

Power: 12 - 24 Vdc, 250 mA minimum

Materials:

Mechanical: 316 SS/PVC

Electrodes: Hastelloy

Electrode plate: PVDF

Housing Cast: powder-coated aluminum

O-rings: EPDM

Size: 4 inch square; 6-7 inches total length (10.2 cm square; 15.2 to 17.8 cm total length)

Weight: 2 lbs (907g)